Unit-injectors UIS/ UPS
Test benches and equipment for testing unit injectors and PLD sections
CAMBAT-FLOW
- Description
- Package contents
- Extra
CAMBAT-FLOW. Equipment for testing and checking Unit-Injectors and Pump sections of the UIS/UPS system
The kits “CAMBAT-FLOW”, “CAMBAT-FULL” and “CAMBAT-FULL-SET” are designed for diagnostics unit injectors and pump sections manufactured by Bosch, Denso, Delphi, Siemens (VDO) at the workbench. Testing of pump injectors is provided by supplying a control signal from the equipment to the tested pump injectors and maintaining the required pressure in the system according to the selected test plan.
The equipment provides:
- control of 1 pump-injector;
- pressure control in the system in manual and automatic mode;
- control of electromagnetic pump-injectors of a passenger series from a voltage of 14V;
- control of electromagnetic pump-injectors of the cargo series from a voltage of 36V;
- control of piezoelectric pump injectors;
- control of the shutter measuring block;
- disabling control in the absence of a protective screen in a test area;
- stop control of the drive bench injection pump after complete of the test;
- temperature measurement in the tank;
- measurement of injector backflow temperature;
- measurement of injection start time;
- cooler and heater control;
- measurement flow/overflows of injectors;
* frequency converter control;
* Functions are additional options and are not included in the basic version of the equipment!
CAMBAT-FLOW |
||||
№ | Article | Name | Count | Photo |
1 | Passport, (technical description, instruction manual) | 1 pc | ||
2 | CAMBAT-FLOW | Flow meter for unit injectors and pump sections of the UIS/UPS system | 1 pc | |
3 | Set of 4 wheels for moving the mobile measuring unit | 1 set | ||
4 | DL-P1004 | Teflon tube Ø6 mm | 3 m | |
5 | DL-P1008 | Teflon tube Ø10 mm | 3 m | |
6 | Fitting Ø10 angled to connect the drain to the tank | 1 pc | ||
7 | Nut + rubber-metal. washer for fixing the angle fitting | 1 pc | ||
8 | Fitting Ø10 tee for draining the sump of the measuring unit | 2 pc | ||
9 | Fitting Ø10 straight for connecting the drain of the measuring unit | 2 pc | ||
10 | Mobile unit door opener key | 2 pc | ||
CAMBAT-FULL |
||||
№ | Article | Name | Count | Photo |
1 | CAMBAT-FLOW | A set consisting of a mobile unit for measuring the injection of unit injectors and accessories | 1 set | |
2 | UIS-Tester | Equipment for testing unit injectors | 1 pc | |
3 | Extension for injector cables: socket “Injector” 1.5m | 1 pc | ||
4 | Adapter cable for injectors (6 pcs) | 1 set | ||
5 | Power cable 220 V | 1 pc | ||
6 | Temperature sensor for monitoring the temperature of the liquid in the tank “Tank t C” | 1 pc | ||
7 | Digital inverter cable | 1 pc | ||
8 | Cable “Analog inverter” | 1 pc | ||
9 | Cable “Output signal” | 1 pc | ||
10 | Cable “Thermocontroller” | 1 pc | ||
11 | Cable “Relay” | 1 pc | ||
12 | Cable “USB” | 1 pc | ||
13 | Cables for connecting the UIS-tester to the mobile measurement unit | 1 set | ||
14 | Cascade Software | 1 set | ||
15 | Mounting parts of the UIS-tester to the mobile measuring unit | 1 set | ||
CAMBAT-FULL-SET |
||||
№ | Article | Name | Count | Photo |
1 | СAMBAT-FULL | Mobile measuring unit with installed control unit UIS-tester, measuring system and necessary connecting cables | 1 set | |
2 | Cam-Box2 MECHANIC | Mechanical part for testing pump injectors and PLD sections (UIS/UPS system) | 1 pc | |
3 | DL-CB20124 | Clamp-adapter No. 0124 for pump injectors Volvo FH12, Iveco (Bosch) | 1 pc | |
4 | DL-CB230035 | Connection fitting M14(x1.5) x 1/4″ | 2 pc | |
5 | Rubber-metal washer Ø M14 2pcs and 1/4″ 2pcs | 1 set | ||
6 | DL-CB20123 | Clamp adapter #0123 for PLD NF sections #0129 ,133, 144 | 1 pc | |
7 | DL-CB250061 | Test nozzle holder for clamp adapter CB20123 | 1 set | |
8 | DL-CB20100 | Clamp-adapter #0100 for installing the indicator head and calibrating Cam Box 2, fixing bolt M4x10 1pc | 1 pc | |
9 | DL-CB230010 | Atomizer nozzle bracket, OKS M8x20 bracket mounting bolt 2pcs | 1 pc | |
10 | – | Bolts for fixing the spray nozzle to the nozzle M10x106mm + M10x56mm | 2 pc | |
11 | DL-CB230012 | Spray nozzle Ø9mm, spacer, res.met. gasket, quick-release adapter Ø6mm | 1 set | |
12 | DL-СВ230022 | Clamp bracket, bolt fastening bracket OKS M8x20 2pcs | 1 pc | |
13 | DL-CB230046, DL-CB230047, DL-CB230048, DL-CB230049 | Sprayer sealing washers | 1 set | |
14 | DL-CB230013 | Cam Stroke Locks and Cam Top/Bottom Dead Center Lock | 1 set | |
15 | DL-CB230084 | Distance sleeve H=7, Ø 20mm, mounted on Cam Box 2 rails, used for light pump injectors. | 2 pc | |
16 | DL-CB230189 | Distance washer H=5, Ø12mm for adapter mounting bolts | 2 pc | |
17 | DL-CB230109 | Pusher screw for injector pump, spherical | 1 pc | |
18 | DL-CB230134 | Pusher screw for injector pump, spherical short | 1 pc | |
19 | DL-CB230135 | Screw pusher for injector pump inner | 1 pc | |
20 | DL-CB230043 | Pusher screw for pumping sections, fixing nut M12x1.25 1pc | 1 pc | |
21 | DL-CB250001 | Gauge adjustable for setting the preload injector pump with fixing bolt | 1 pc | |
22 | – | Hose for inlet/outlet of TF pumping to adapter Ø10x1000mm | 2 pc | |
23 | – | Clamps Ø12mm, fittings, bolts Banjo M14x1.5, gaskets cut-metal. ØM14 for testfuel pumping hoses | 1 set | |
31 | DL-5358 | Compensation spring (red L=76mm) with a stroke of 10-12mm with a pusher | 1 set | |
32 | D-6280 | Compensation spring (grey) with pusher | 1 set | |
33 | DL-UNI30089 | Profile T-bolts for fastening Cam Box 2, complete with washers and nuts, M14x44mm | 2 sets | |
34 | – | Back flow pressure valve for pumping from adapter 2.5 bar | 1 pc |