Common-Rail
Equipment for testing of Common Rail pumps
FMDE-500
- Description
- Package contents
- Extra
FMDE-500. Digital two-channel flowmeter
FMDE-500. Digital two-channel flowmeter
The device “FMDE-500” is designed for testing and checking the performance of diesel high pressure fuel pumps of the Common Rail system.The device has two channels for measuring the flow. The first channel has a two-stage flow measurement to provide a larger measuring range for the fluid flow. In each measuring channel of the strait there is a temperature sensor that measures the temperature of the incoming fluid flow.
Device “FMDE-1520” | 1 pc. |
Supply cable 220 V | 1 pc. |
USB Cable | 1 pc. |
External filter (50 mc) | 2 pc. |
Software “DieselTest” | 1 pc. |
Manual “FMDE-1520” | 1 pc. |
Main technical data and characteristics
Measured flow range: | |
Channel 1. Sensor 1. | 0,1 — 2,5 l/min. 6-150 l/h |
Channel 1. Sensor 2. | 0,5 — 8,33 l/min. 30-500 l/h |
Flow measurement error: | |
Channel 1. Sensor 1. | 3% |
Channel 2. Sensor 2. | 6-150 l/h no more than: +/- 2l/h |
Channel 2. Sensor 2. | more than 150 l/h: no more than1% |
Repeatability | 0,5% |
Permissible flow temperature range of the measured flow | -20 – +90 °C |
Error of flow temperature measurement, not more than | +/-2°C |
Supply voltage | ~220 V ±15% |
Device Weight | 6 kg |
Dimensions (length x width x height) | 365 х 322 х 110 |
Consumed power, no more than | 24 Wt |