High pressure fuel pumps VE/ VP / P / PE
Test benches for diesel fuel equipment
SPF-1108
- Description
- Package contents
- Characteristics
SPF-1108. Assay test bench for testing high-pressure fuel pumps
SPF-1108
Assay test bench for testing high-pressure fuel pumps
POWER OF THE BASIC DRIVE 11kW
MEASURING UNIT OF 8 MEASURING FLASKS
TESTING TYPES
The assay test bench allows the following types of tests and adjustments:
determination of the volume of fuel injection doses for different shaft speeds of the high-pressure fuel pump, corresponding to:
- engine start (starting dose),
- idling (dose of idling),
- the beginning and end of the positive and negative adjustment,
- engine rated power (nominal, so-called measuring dose), as well as revolutions, defining the so-called high-speed characteristic of a high-pressure fuel pump;
- determining the speed of rotation of the start and end of the fuel injection shutdown by the rotation speed regulator (maximum idling speed), defining the so-called adjustable speed range;
- geometric start of compression (adjustment of the preliminary stroke), as well as angular gaps between sections of the high-pressure fuel pump;
- scatter (non-uniformity) of doses of fuel injected by different sections of the high-pressure fuel pump, which should not exceed 2% of the nominal dose;
- operation of the electromagnetic shut-off valve;
- checking the suction discharge of the feed pumps;
- checking the injection pressure of the feed pumps;
- checking the performance of feed pumps;
- check of tightness and permeability of the fuel filter.
Scheme
Name | Quantity |
Flexible piping 3/8”L- 105 sm | 2 pc |
Tips for 14 mm | 2 pc |
Tips for 12 mm | 2 pc |
Connecting hose Ø 8 mm L- 150 sm | 1 pc |
Connecting hose Ø 10 мм L- 150 см | 1 pc |
Wrench for doors | 4 pc |
Foot (with regulation bolt) | 4 pc |
TECHNICAL SPECIFICATIONS | |
rotation speed | 30 – 3500 min-1 |
direction of rotation | left/right |
Output power | 12 kW (rated) -11kW |
torque | 1050-3000 min-1: 68.2-24.2 Nm |
Programmable number of injections (every 50) | 50 to 1,000 |
Tank capacity | approx. 30 dm3 |
Number of metering units | 8 |
flask volume | 44 and 260 +/- 0.25 sm3 |
power supply | 3x400V / 230V ~ 50Hz |
maximal current strength | 29A |
heater power of testing liquid | 1000W |